Electrolux Fridge Error Codes

Select form the list of Electrolux Fridge error codes below for the code meaning and possible issues that may be causing the fault to display.

Electrolux Fridge Error Codes

The Electrolux Fridge error codes listed above may also apply to the following brands.

  • AEG Fridge error codes.
  • Anova Fridge error codes.
  • Frigidaire Fridge error codes.
  • Westinghouse Fridge error codes.
  • Zanussi Fridge error codes.

Why is my Electrolux Fridge displaying error codes?

Your Electrolux Fridge will display error codes when the main control panel internal diagnostics system has detected a problem.

How can I reset Electrolux Fridge Error Codes

The first thing to try is switching the Fridge main power supply off for 60 seconds. This usual only works if the fault was set due to a supply voltage fluctuation from a storm or power outage. It may also work if the problem is intermittent. Unfortunately this might only be a short term solution because if the problem is intermittent and the fault returns, the error code will display again.

If that doesn’t work, the problem triggering the error code will need to be repaired in order to clear the fault code.

Why is my Electrolux Fridge not working?

Some Electrolux Fridge error codes will disable the appliance from operating. The error code will need to be resolved in order for the appliance to function normally again.

What does 2 mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 2 fault code, it is indicating a Freezer or Fridge Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An 2 Freezer or Fridge Temperature Sensor (thermistor) Error will set if the control board detects The freezer or fridge temperature sensor (thermistor) is open.

The most common issues that will cause an 2 Freezer or Fridge Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the 2 code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does 2X mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 2X fault code, it is indicating a Perfect Temperature Drawer Error has been detected by the internal self diagnostics system.

An 2X Perfect Temperature Drawer Error will set if the control board detects The PTD temperature sensor (thermistor) is open.

The most common issues that will cause an 2X Perfect Temperature Drawer Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The control board is defective.
  • Wiring issue between the temperature sensor (thermistor) and the control board.

Try turning the Fridge main power supply off for 1 minute. If the 2X code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does 3 mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 3 fault code, it is indicating a Freezer or Fridge Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An 3 Freezer or Fridge Temperature Sensor (thermistor) Error will set if the control board detects The freezer or fridge temperature sensor (thermistor) is shorted.

The most common issues that will cause an 3 Freezer or Fridge Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the 3 code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does 3X mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 3X fault code, it is indicating a Perfect Temperature Drawer Error has been detected by the internal self diagnostics system.

An 3X Perfect Temperature Drawer Error will set if the control board detects The PTD temperature sensor (thermistor) is shorted.

The most common issues that will cause an 3X Perfect Temperature Drawer Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The control board is defective.
  • Wiring issue between the temperature sensor (thermistor) and the control board.

Try turning the Fridge main power supply off for 1 minute. If the 3X code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does 4 mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 4 fault code, it is indicating a Air Damper Error has been detected by the internal self diagnostics system.

An 4 Air Damper Error will set if the control board detects The air damper is not moving.

The most common issues that will cause an 4 Air Damper Error to display on an Electrolux Fridge are:

  • The air damper is defective.
  • The air damper is jammed.
  • The main PCB is defective.
  • Wiring issue between the air damper and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the 4 code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does 9X mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an 9X fault code, it is indicating a Perfect Temperature Drawer Error has been detected by the internal self diagnostics system.

An 9X Perfect Temperature Drawer Error will set if the control board detects A PTD keypad key is shorted.

The most common issues that will cause an 9X Perfect Temperature Drawer Error to display on an Electrolux Fridge are:

  • The PDT UI board is defective.
  • The PDT main board is defective.
  • Wiring issue.

Try turning the Fridge main power supply off for 1 minute. If the 9X code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does bS mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an bS fault code, it is indicating a Ice Maker Function Error has been detected by the internal self diagnostics system.

An bS Ice Maker Function Error will set if the control board detects Both switches error

The most common issues that will cause an bS Ice Maker Function Error to display on an Electrolux Fridge are:

  • The ice maker assembly is defective.
  • The ice maker is jammed.
  • The main PCB is defective.
  • Wiring issue between the ice maker and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the bS code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does CE mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an CE fault code, it is indicating a Communication Error has been detected by the internal self diagnostics system.

An CE Communication Error will set if the control board detects Version error between the ice maker and the ERF 2500++ system controller.

The most common issues that will cause an CE Communication Error to display on an Electrolux Fridge are:

  • The ice maker is defective.
  • The ERF 2500++ system controller is defective.
  • Wiring issue between the ice maker and the ERF 2500++ system controller.

Try turning the Fridge main power supply off for 1 minute. If the CE code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does dF mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an dF fault code, it is indicating a Freezer Defrost Heater Loop Error has been detected by the internal self diagnostics system.

An dF Freezer Defrost Heater Loop Error will set if the control board detects The freezer defrost loop is open or the defrost operation has taken longer than expected.

The most common issues that will cause an dF Freezer Defrost Heater Loop Error to display on an Electrolux Fridge are:

  • The defrost heater is defective.
  • The defrost temperature sensor (thermistor) is defective.
  • The defrost high limit sensor is defective.
  • The main PCB is defective.
  • Wiring issue between the defrost loop and the main PCB.
  • The defrost room is overwhelmed with ice.

Try turning the Fridge main power supply off for 1 minute. If the dF code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does Er mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an Er fault code, it is indicating a Ice Maker RAM Error has been detected by the internal self diagnostics system.

An Er Ice Maker RAM Error will set if the control board detects Communication error between the ice maker and the ERF 2500++ system controller.

The most common issues that will cause an Er Ice Maker RAM Error to display on an Electrolux Fridge are:

  • The ice maker is defective.
  • The ERF 2500++ system controller is defective.
  • Wiring issue between the ice maker and the ERF 2500++ system controller.

Try turning the Fridge main power supply off for 1 minute. If the Er code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does FIL mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an FIL fault code, it is indicating a Ice Maker Function Error has been detected by the internal self diagnostics system.

An FIL Ice Maker Function Error will set if the control board detects Fill limit switch error.

The most common issues that will cause an FIL Ice Maker Function Error to display on an Electrolux Fridge are:

  • The ice maker assembly is defective.
  • The ice maker is jammed.
  • The main PCB is defective.
  • Wiring issue between the ice maker and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the FIL code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does FrE mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an FrE fault code, it is indicating a Ice Maker Function Error has been detected by the internal self diagnostics system.

An FrE Ice Maker Function Error will set if the control board detects Freeze switch error.

The most common issues that will cause an FrE Ice Maker Function Error to display on an Electrolux Fridge are:

  • The ice maker assembly is defective.
  • The ice maker is jammed.
  • The main PCB is defective.
  • Wiring issue between the ice maker and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the FrE code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does H mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an H fault code, it is indicating a Ice Maker Function Error has been detected by the internal self diagnostics system.

An H Ice Maker Function Error will set if the control board detects Harvest motor error.

The most common issues that will cause an H Ice Maker Function Error to display on an Electrolux Fridge are:

  • The ice maker assembly is defective.
  • The ice maker is jammed.
  • The main PCB is defective.
  • Wiring issue between the ice maker and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the H code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does HI mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an HI fault code, it is indicating a Perfect Temperature Drawer Error has been detected by the internal self diagnostics system.

An HI Perfect Temperature Drawer Error will set if the control board detects The PTD over temperature has exceeded the timeout.

The most common issues that will cause an HI Perfect Temperature Drawer Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The heating element is defective.
  • The control board is defective.
  • Wiring issue.

Try turning the Fridge main power supply off for 1 minute. If the HI code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does IP mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an IP fault code, it is indicating a Ice Maker Invalid Protocol Error has been detected by the internal self diagnostics system.

An IP Ice Maker Invalid Protocol Error will set if the control board detects Version error between the ice maker and the ERF 2500++ system controller.

The most common issues that will cause an IP Ice Maker Invalid Protocol Error to display on an Electrolux Fridge are:

  • The ice maker is defective.
  • The ERF 2500++ system controller is defective.
  • Wiring issue between the ice maker and the ERF 2500++ system controller.

Try turning the Fridge main power supply off for 1 minute. If the IP code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does LO mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an LO fault code, it is indicating a Perfect Temperature Drawer Error has been detected by the internal self diagnostics system.

An LO Perfect Temperature Drawer Error will set if the control board detects The PTD under temperature has exceeded the timeout.

The most common issues that will cause an LO Perfect Temperature Drawer Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The heating element is defective.
  • The control board is defective.
  • Wiring issue.

Try turning the Fridge main power supply off for 1 minute. If the LO code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does OP mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an OP fault code, it is indicating a Freezer or Fridge Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An OP Freezer or Fridge Temperature Sensor (thermistor) Error will set if the control board detects The freezer or fridge temperature sensor (thermistor) is open.

The most common issues that will cause an OP Freezer or Fridge Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the OP code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does Sb mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an Sb fault code, it is indicating a Sabbath Mode has been detected by the internal self diagnostics system.

An Sb Sabbath Mode will set if the control board detects Sabbath mode is active.

The most common issues that will cause an Sb Sabbath Mode to display on an Electrolux Fridge are:

  • The Sabbath Mode is a feature that disables portions of the fridge and its controls in accordance with observance of the Sabbath and religious holidays within the Orthodox Jewish community. Sabbath Mode is turned ON and OFF by pressing and holding “∨” on freezer temp and “∧” on refrigerator temp for five seconds.

Try turning the Fridge main power supply off for 1 minute. If the Sb code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does SH mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an SH fault code, it is indicating a Freezer or Fridge Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An SH Freezer or Fridge Temperature Sensor (thermistor) Error will set if the control board detects The freezer or fridge temperature sensor (thermistor) is shorted.

The most common issues that will cause an SH Freezer or Fridge Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the SH code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does SY CE mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an SY CE fault code, it is indicating a Communication Error has been detected by the internal self diagnostics system.

An SY CE Communication Error will set if the control board detects Communication error between the main PCB and the control panel.

The most common issues that will cause an SY CE Communication Error to display on an Electrolux Fridge are:

  • The control panel is defective.
  • The main PCB is defective.
  • Wiring issue between the control panel and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the SY CE code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does SY CF mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an SY CF fault code, it is indicating a Communication Error has been detected by the internal self diagnostics system.

An SY CF Communication Error will set if the control board detects Communication error between the main PCB and the control panel.

The most common issues that will cause an SY CF Communication Error to display on an Electrolux Fridge are:

  • The control panel is defective.
  • The main PCB is defective.
  • Wiring issue between the control panel and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the SY CF code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does SY EF mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an SY EF fault code, it is indicating a Freezer Evaporator Fan Motor Error has been detected by the internal self diagnostics system.

An SY EF Freezer Evaporator Fan Motor Error will set if the control board detects The freezer evaporator fan motor is not turning.

The most common issues that will cause an SY EF Freezer Evaporator Fan Motor Error to display on an Electrolux Fridge are:

  • The fan motor is defective.
  • The fan blade is jammed.
  • The main PCB is defective.
  • Wiring issue between the fan motor and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the SY EF code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does T1 mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an T1 fault code, it is indicating a Ice Maker Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An T1 Ice Maker Temperature Sensor (thermistor) Error will set if the control board detects The ice maker Temperature sensor (thermistor) signal is out of range.

The most common issues that will cause an T1 Ice Maker Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the T1 code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

What does T3 mean on an Electrolux Fridge?

If your Electrolux Fridge is displaying an T3 fault code, it is indicating a Ice Maker Temperature Sensor (thermistor) Error has been detected by the internal self diagnostics system.

An T3 Ice Maker Temperature Sensor (thermistor) Error will set if the control board detects The ice maker Temperature sensor (thermistor) signal is out of range.

The most common issues that will cause an T3 Ice Maker Temperature Sensor (thermistor) Error to display on an Electrolux Fridge are:

  • The temperature sensor (thermistor) is defective.
  • The main PCB is defective.
  • Wiring issue between the temperature sensor (thermistor) and the main PCB.

Try turning the Fridge main power supply off for 1 minute. If the T3 code returns after turning the power supply back on, the problem causing the fault will need to be repaired to clear the error

Electrolux Fridge Error Codes Disclaimer

The Electrolux Fridge Error Codes information contained on this page is provided for informational purposes only. ApplianceFaultCodes.com does not guarantee the information to be correct or give a proper diagnosis of any appliance. Always take proper safety precautions when installing or repairing any major appliance.